Pupil Simulator:
shine a light on
your understanding.
You know to check the pupils. But are you confident explaining what you see when the light moves?
Free demo. No account needed. Full controls and Decoding the Pupil are available in the premium community.
When “the pupils react” does not quite answer your question
You cannot choose the pupil responses of your clinical partner, nor the patient who may book into your clinic. You might practise the technique many times before seeing a clear example of the sign you have been learning about.
Then something looks different. Was that a weaker response? Did both pupils change? Were you watching the right eye at the right moment? If you have ever wanted someone to slow it down and explain what happened, this is a place to start.
“I have never seen an RAPD clearly.”
Compare normal pupils with a marked teaching example. Repeat the sequence and focus on what changes when you illuminate each eye.
“I am doing the test but not understanding the response.”
Use the prompts below to follow both pupils. Describe the observation first, then connect it with what you know about the pathway.
“I want to feel more prepared for clinic.”
Revisit an example without the pressure of a patient waiting. Take a clearer question into your next supervised session and keep building from there.
The aim is to give your theory something visible to connect to. You do not need to understand every pupil abnormality in one sitting.
Try the free Pupil Simulator
Choose Normal pupils first, then compare the Marked RAPD example. In this demo the RAPD affects the patient’s right eye, which appears on your left as you face the model.
A little guide to the demo: move the torch with the tracking pad, drag it between the eyes, or use the eye buttons. You can switch the light on and off, or let the automated swinging light sequence run. The demo keeps the room dim, fixation at distance, brightness fixed and light distance equal at 20 cm, so you can concentrate on the responses. Grey controls show some of the extra options available in the full version.
A tablet or computer gives you more room to watch both pupils. On a phone, try landscape and the simulator’s Fullscreen control. Use its exit control, or Escape on a keyboard, to leave fullscreen.
The demo loads when you press Start.
Teaching only. Pupil appearances, timings and size readouts are illustrative, not clinically calibrated measurements. Use alongside teaching and supervised practice, rather than to diagnose a patient.
Try this: watch both pupils, then explain the difference
- Start with the normal example. Illuminate the patient’s right eye and watch both pupils. The response in the illuminated eye is direct; the response in the fellow eye is consensual. Swap sides and compare.[1]
- Change to the marked right RAPD. Repeat the sequence. Compare the strength of the response in both pupils when the right eye receives the light with the response when the left eye receives it. An RAPD is a relative difference in afferent input between eyes.[2]
- Let the sequence run. Choose Automation and Start. The demo uses three seconds on each eye, at equal 20 cm light distances. Pause when you want to talk it through; Resume continues the sequence. Stop returns to the previous examination.
- Put it into words. Which eye was illuminated when both pupils responded less strongly? Say that out loud before naming the side of the RAPD. Remember that pupil sizes alone do not tell you whether an RAPD is present.[2]
What does “relative dilation” mean here?
When the light moves from the better afferent eye to the affected eye, both pupils may dilate relative to their preceding constricted state. The important comparison is the response with light on one eye versus the other, rather than every small change while the torch crosses between them.[1]
In a real examination, pupil size and shape, light responses, symptoms and the rest of your findings all contribute to interpretation. Unequal pupils can be physiological, but pupil abnormalities can also signal significant disease.[3]
Keep the clinical context in view. New pupil findings need appropriate assessment. Acute painful Horner’s syndrome, or new diplopia, ptosis or a nerve palsy, requires emergency escalation in line with the presentation and local pathway. Do not delay care while trying to match an animation.[4]
A bridge between the lecture slide and the clinic
In a study of 51 pre-clinical optometry students, learners reported benefits from a virtual clinic learning activity, including motivation and perceived clinical reasoning development. The study used a different resource, but it offers encouraging evidence about students’ experience of virtual clinical learning.[5]
Here, the practical idea is to make space for repetition and explanation. You can revisit the same response, compare it with normal and work out what you want to ask next. Your supervised clinical experience then helps connect that understanding with real patients.
Go further with the full simulator and Decoding the Pupil
If the demo helps something click, the full Pupil Simulator gives you a wider set of examples and controls to explore inside The Eye Care Advocate’s premium community.
| What you can explore | Free demo | Full version |
|---|---|---|
| Clinical examples | Normal pupils and marked right RAPD | Further examples including physiological anisocoria, milder RAPD, third-nerve palsy, Horner syndrome, Adie tonic pupil and structural iris variations |
| Torch and assessment | Manual light control; fixed brightness, 20 cm distance and dim room; distance fixation | Additional brightness, distance, room-light and fixation controls |
| Automation | Repeating swinging light sequence, three seconds per eye and equal light distances | Further sequences and adjustable settings |
| Appearance and laterality | Advocate purple irides; RAPD fixed to the patient’s right | Further iris colours, involved-eye options and condition-specific controls |
| Challenge mode | Preview only | 20-question Challenge |
Full functionality is accessed within the community. Joining does not unlock this embedded demo. All examples remain teaching illustrations.
Pair the movement with the explanation
Decoding the Pupil, also titled Beyond PERRLA: Decoding the Pupil, is included in membership too. Use the course alongside the simulator to revisit pupil assessment and connect what you are learning with the responses you can see.
You also gain access to practical courses including Ret Mess to Ret Success and the Slit Lamp Handbook, further simulators and calculators, MCQs, digital access to History & Symptoms: The Eye Examination, and a community for learning questions and shared experiences.
There are free optometry resources across this website too. Membership brings the fuller tools, courses and shared learning together.
£15 a month or £150 a year
Both plans provide the same access. Annual membership is billed as £150, saving £30 compared with twelve £15 monthly payments. Recurring membership; check the current price, renewal and cancellation terms before joining.
Start with the free demo and see whether this approach helps you learn.
Pupil assessment questions you might have been meaning to ask
What is the Pupil Simulator for?
It is a teaching tool for exploring illustrated pupil responses, comparing examples and practising your explanation of what you observe. It supports optometry students, educators and professionals revisiting the foundations alongside supervised practice.
Which cases can I try for free?
The demo includes normal pupils and a marked right RAPD. Manual torch controls and the fixed automated swinging light sequence are available. Grey controls and the 20-question Challenge preview show features of the full community version.
What is the difference between a direct and a consensual response?
The direct response occurs in the illuminated eye; the consensual response occurs in the fellow eye. Watch both pupils while illuminating one eye, then repeat on the other side.[1]
Does an RAPD mean one pupil is larger than the other?
No. An isolated RAPD is an afferent comparison and does not itself cause anisocoria. Compare how the pupils respond to illumination of each eye, rather than using unequal resting pupil size to identify it.[2]
Why can both pupils change when the RAPD affects only one eye?
Light input from either eye contributes to both pupils’ responses. A weaker afferent signal from one eye therefore affects the response observed in both pupils when that eye is illuminated, provided their efferent responses are intact.[1]
Does no RAPD mean the optic nerves and retina are healthy?
No. The test compares the two eyes. Symmetrical bilateral afferent disease may produce no relative defect, so interpret the finding with vision, fields, ocular examination and the wider clinical picture.[2]
How can I practise when I rarely see abnormal pupil responses?
Start with normal, predict what should happen, then compare the marked example. Repeat it and describe the eye receiving the light and the responses you observe. Take one specific question to your tutor or supervisor rather than expecting yourself to recognise every pattern immediately.
Is anisocoria always an emergency?
No. Physiological anisocoria is common, but unequal pupils can also have significant causes. Onset, symptoms, light and dark appearances, lids and eye movements help determine the next step. Do not decide urgency from a simulator resemblance alone.[3]
When should a new pupil finding prompt urgent escalation?
Use current guidance and your local pathway. College guidance lists painful Horner’s syndrome and acute onset diplopia, squint, ptosis or nerve palsy for emergency referral within 24 hours; some presentations need more immediate action. Seek senior advice rather than delaying.[4]
Can I diagnose patients or measure pupil sizes with this simulator?
No. Its readouts, response timings and animations are illustrative. Patient measurements, clinical assessment and management decisions require appropriate clinical methods and professional judgement.
Is Decoding the Pupil included with the full simulator?
Yes. The premium community includes the full Pupil Simulator and Decoding the Pupil course, alongside further courses, simulators, calculators, MCQs and community learning. Both membership plans provide the same access.
Where can I find more resources for optometry students?
Explore the free Skill Centre and Students’ Corner. The premium community brings the full simulators and courses together with shared learning.
Before you move on, what made more sense?
A couple of sentences is plenty. Record what you learnt and take one useful question into your next supervised session.
Your responses stay in this open page. They are not sent to me or saved automatically. Print or save them before leaving, and avoid entering patient information. This is a personal learning record, not an accredited CPD certificate.
References
- American Academy of Ophthalmology EyeWiki (n.d.). Reflexes and the eye. Accessed 2 November 2026.
- American Academy of Ophthalmology EyeWiki (n.d.). Relative afferent pupillary defect. Accessed 2 November 2026.
- College of Optometrists (2024). Abnormalities of the pupil. Clinical management guidelines. Accessed 2 November 2026.
- College of Optometrists (n.d.). Annex 4 urgency of referrals table. Guidance for professional practice. Accessed 2 November 2026.
- Edgar AK, Macfarlane S, Kiddell EJ, Armitage JA, Wood-Bradley RJ (2022). The perceived value and impact of virtual simulation-based education on students’ learning: a mixed methods study. BMC Medical Education 22: 823. doi:10.1186/s12909-022-03912-8.

